AR 50 Analog

ER50
ER50

  Stat
Rated voltage 24Vdc
Rated current 2A(1)
Starting current 5A(1)
Power consumption (Max) 50W
Ambient temperature in operation 0 °C to +40 °C, non-condensing
Compatible NDW controllers Compatible with controllers with an analog interface. E.g BWU3290, BWU2478 and similar.
Motor connector type and cable length M8 5-pin, male, snap-in, B-coded, length 900mm
Motor shaft Stainless steel, 11 mm hexagon, thread M12 x 1.75
Tube 50 x 1.5mm, stainless steel or zinc-plated steel
Stall protection If motor is stalled for more than 2 seconds, the motor will stop and the error signal will become low. To reset turn the power off and on again. 
Overvoltage protection / Overcurrent protection No. Current cap to be provided by controller. 
Do not use in overload condition, which is higher than 5A for longer than 2 seconds. 
Overcurrent protection module available separately. 
See page 7, accessories for article number. 
Protection rate IP54
Maximum Noise level 55 dB(2)
Minimum conveyor frame width for E-roller IL = 275 mm (Poly-v transmission)

1. Actual current is depended on the conditions of the application, such as actual load, section length, slope etc. 
2. Measured at 1 meter. Also dependent on the conditions of the application, such as conveyor frame, mounting type, load and resonance behavior of the system

ER50